Screw spindle pumps with their silicon carbide spindle housing and highly wear resistant spindles are capable of achieving extremely high pressures.
Brinkmann high pressure screw pumps are designed for pumping filtered and lubricating fluids such as coolant oils and watersoluble coolants.
High pressure screw pumps are NOT designed for dry-running.



Screw spindles

FFS4


TFS4, FFS4 60 Hz
TFS4, FFS4 60 Hz

Technical drawing


FFS4

Screw Spindle Pumps - FFS4

FFS4


Power
2-poles
Power
4-poles
BCDEFHTUVWXYZ
HPHPInchInchInchInchInchInchInchInchInchInchInchInchInch
-3 / 47.806.5412.648.587.4038.150.898.469.849.067.280.550.59
-58.746.9713.078.587.4037.480.898.469.849.067.280.550.59
7.5-10.317.9515.249.767.8339.760.8910.4311.8110.638.860.550.71
107.510.317.9515.249.767.8341.730.8910.4311.8110.638.860.550.71
-1010.317.9515.249.767.8342.090.8910.4311.8110.638.860.550.71
15 / 201512.369.3318.5811.738.8245.870.7911.8113.7812.0110.430.710.71
252012.369.3318.5811.738.8248.230.7911.8113.7812.0110.430.710.71
-2514.0211.2620.5111.738.8248.390.7911.8113.7812.0110.430.710.71
30-14.0211.2620.5111.738.8248.230.7911.8113.7812.0110.430.710.71
-3014.0211.2620.5111.738.8249.570.7911.8113.7812.0110.430.710.71
40-15.5912.4022.6412.728.4350.470.9813.7815.7513.7811.810.710.79
504015.5912.4022.6412.728.4351.460.9813.7815.7513.7811.810.710.79
60-17.6813.3122.1711.3419.4954.530.9814.0217.1714.2112.240.751.34
75-19.5716.1425.9812.3221.5457.361.1815.9819.2916.1013.740.941.57



Applications

Types of fluidcoolants
cooling/cutting oils
Oils
Kinematic viscosity4.6...200 SSU (1...45 mm²/s)
higher viscosity upon request
Max. air content3 - 5 vol. %
Pumping temperaturemax. 140 °F (60° C)
higher temperatures upon request
Recommended filtration levelsGeneral Machining (Turning, milling, drilling) < 50 µm
Grinding and machining of aluminum < 20 µm
For additional information please refer to mechanical features within the technical information section.

Construction

Suction Housing

Pressure and Cast iron
Spindle HousingSilicon Carbide, one-piece, highly wear resistant and precision
Screw spindlesHardened tool steel specially treated, alloy; highly wear resistant and precision ground
GasketViton ®


Motor 2-poles
rotation speed 3500 min-1
Motor 4-poles
rotation speed 1750 min-1
Pressure max. Flow at viscosity Power consumption of viscosity Motor Weight Flow at viscosity Power consumption of viscosity Motor Weight
  5 SSU 90 SSU 5 SSU 90 SSU NEMA   5 SSU 90 SSU 5 SSU 90 SSU NEMA  
Type / bar / PSI GPM GPM HP HP HP Lbs GPM GPM HP HP HP Lbs
FFS460/ QTh1)39.9 - - - - QTh1)20.0 - - - -
10 /  145 cad  
38.0 38.8 4.4 5.0 7.5 183 18.0 19.0 2.1 2.1 3 150
20 /  290 cad  
37.3 38.6 7.8 8.6 10 212 17.2 18.5 3.8 3.9 5 150
30 /  435 cad  
36.5 38.0 11.3 12.1 15 254 16.6 18.2 5.5 5.8 7.5 159
40 /  580 cad  
35.9 37.8 14.6 15.7 20 273 15.9 17.7 7.1 7.5 10 227
50 /  725 cad  
35.1 37.5 18.0 19.3 25 296 15.1 17.4 8.9 9.4 10 227
60 /  870 cad  
34.6 37.0 21.3 22.8 25 296 14.5 17.2 10.6 11.3 15 227
70 /  1015 cad  
33.8 36.7 24.7 26.4 30 373 14.0 16.6 12.2 13.0 15 271
80 /  1160 cad  
33.3 36.5 28.2 29.9 40 476 13.2 16.4 13.9 14.9 20 271
90 /  1305 cad  
32.8 36.2 31.5 33.5 40 476 12.7 16.1 15.6 16.6 20 309
100 /  1450 cad  
32.2 35.9 34.9 37.1 40 476 11.9 15.9 17.3 18.5 20 309
110 /  1595 cad  
31.7 35.7 38.2 40.6 50 523 - 15.6 - 20.4 25 309
120 /  1740 cad  
30.9 35.4 41.7 44.3 50 523 - 15.3 - 22.1 25 309
 
FFS480/ QTh1)53.3 - - - - QTh1)26.6 - - - -
10 /  145 cad  
50.7 52.0 5.6 6.6 10 212 24.0 25.4 2.7 2.8 4 150
20 /  290 cad  
49.7 51.3 10.1 11.4 15 254 23.0 24.8 5.0 5.2 7.5 159
30 /  435 cad  
48.6 50.7 14.6 16.2 20 273 22.2 24.0 7.1 7.6 10 227
40 /  580 cad  
47.8 50.2 19.0 20.9 25 296 21.1 23.5 9.4 10.1 15 227
50 /  725 cad  
47.0 49.7 23.6 25.7 30 373 20.3 23.2 11.7 12.5 15 271
60 /  870 cad  
46.2 49.4 28.2 30.6 40 476 19.6 22.7 13.9 14.9 20 271
70 /  1015 cad  
45.4 48.9 32.6 35.4 40 476 18.8 22.2 16.2 17.3 20 309
80 /  1160 cad  
44.6 48.3 37.1 40.2 50 523 18.0 21.9 18.4 19.7 20 309
90 /  1305 cad  
43.9 48.1 41.7 45.1 50 523 17.2 21.4 20.7 22.1 25 309
100 /  1450 cad  
43.3 47.8 46.1 49.8 60 569 16.4 21.1 22.9 24.5 25 384
110 /  1595 cad  
42.5 47.6 50.7 54.6 60 789 - 20.9 - 27.0 30 384
120 /  1740 cad  
41.7 47.3 55.1 59.4 60 789 - 20.6 - 29.4 30 401
 
FFS496/ QTh1)63.9 - - - - QTh1)32.0 - - - -
10 /  145 cad  
61.0 62.1 6.4 7.5 10 212 29.1 30.1 3.1 3.6 5 150
20 /  290 cad  
59.7 61.6 11.9 13.3 15 254 27.7 29.6 5.8 6.4 7.5 227
30 /  435 cad  
58.7 61.0 17.3 19.0 25 296 26.7 29.1 8.4 9.4 10 227
40 /  580 cad  
57.6 60.5 22.7 24.8 30 373 25.6 28.5 11.3 12.2 15 271
50 /  725 cad  
56.5 60.0 28.2 30.6 40 476 24.6 28.0 13.9 15.2 20 271
60 /  870 cad  
55.7 59.4 33.5 36.3 40 476 23.8 27.5 16.6 18.1 20 309
70 /  1015 cad  
54.7 59.2 38.9 42.1 50 523 22.7 27.2 19.3 20.9 25 309
80 /  1160 cad  
53.9 58.7 44.4 47.9 50 523 21.9 26.7 22.0 23.9 25 384
90 /  1305 cad  
53.1 58.1 49.8 53.6 60 789 20.9 26.2 24.7 26.7 30 384
100 /  1450 cad  
52.3 57.9 55.1 59.4 75 955 20.1 25.9 27.5 29.6 30 401
110 /  1595 cad  
51.5 57.3 60.6 65.2 75 955 - 25.4 - 32.6 40 512
120 /  1740 cad  
50.5 56.8 66.0 70.9 75 955 - 24.8 - 35.4 40 512
 

1) QTh: Theoretical flow rate