Skip to main content
Press enter to search

Contact

Contact Form
TFS5, FFS5 60 Hz

60 Hznema

Screw Spindle Pumps TFS5

Screw Spindle Pumps
Screw spindle pumps with their silicon carbide spindle housing and highly wear resistant spindles are capable of achieving extremely high pressures.
Brinkmann high pressure screw pumps are designed for pumping filtered and lubricating fluids such as coolant oils and watersoluble coolants.
High pressure screw pumps are NOT designed for dry-running.



Screw spindles

TFS5


TFS5, FFS5 60 Hz
TFS5, FFS5 60 Hz

Technical drawing


TFS5

Screw Spindle Pumps - TFS5

TFS5

*) Dimensions for 4-pole standard
motor upon request
L = Leakage hole
S = Mounting plate, please refer to
the cut-out of mounting hole



TFS5

Dimensions in Inches / mm
All corners must be deburred!
According to ISO 2768-m

Power
2-poles
Power
4-poles
ABC
HPHPInchInchInch
-7.526.4610.317.95
-1026.8110.317.95
15 / 201530.2012.369.33
-2032.5612.369.33
30-32.5614.0211.26
-3033.9014.0211.26
40-34.8015.5912.40
504035.7915.5912.40
-5036.5717.6813.31
606038.8617.6813.31
757541.6919.5716.14
100-44.5721.6917.05
125-48.9421.6917.05
150-48.7824.2520.28

Applications

Types of fluidcoolants
cooling/cutting oils
Oils
Kinematic viscosity4.6...200 SSU (1...45 mm²/s)
higher viscosity upon request
Max. air content3 - 5 vol. %
Pumping temperaturemax. 140 °F (60° C)
higher temperatures upon request
Recommended filtration levelsGeneral Machining (Turning, milling, drilling) < 50 µm
Grinding and machining of aluminum < 20 µm
For additional information please refer to mechanical features within the technical information section.

Construction

Suction Housing

Pressure and Cast iron
Spindle HousingSilicon Carbide, one-piece, highly wear resistant and precision
Screw spindlesHardened tool steel specially treated, alloy; highly wear resistant and precision ground
GasketViton ®


Motor 2-poles
rotation speed 3500 min-1
Motor 4-poles
rotation speed 1750 min-1
Pressure max. Flow at viscosity Power consumption of viscosity Motor Weight Flow at viscosity Power consumption of viscosity Motor Weight
  5 SSU 90 SSU 5 SSU 90 SSU NEMA   5 SSU 90 SSU 5 SSU 90 SSU NEMA  
Type / bar / PSI GPM GPM HP HP HP Lbs GPM GPM HP HP HP Lbs
TFS574/ QTh1)77.0 - - - - QTh1)38.5 - - - -
10 /  145 cad  
74.0 75.3 8.3 9.4 15 313 35.4 36.7 3.9 4.6 7.5 218
20 /  290 cad  
72.9 74.8 14.8 16.2 20 333 34.3 36.2 7.2 8.0 10 287
30 /  435 cad  
71.9 74.2 21.3 23.1 30 432 33.3 35.7 10.5 11.4 15 331
40 /  580 cad  
71.1 73.7 27.8 29.8 40 536 32.5 35.4 13.7 14.9 20 331
50 /  725 cad  
70.3 73.4 34.3 36.6 40 536 31.7 34.9 16.9 18.4 20 368
60 /  870 cad  
69.2 72.9 40.9 43.4 50 582 30.9 34.3 20.2 21.7 25 368
70 /  1015 cad  
68.7 72.4 47.3 50.3 60 849 30.1 34.1 23.5 25.2 30 443
80 /  1160 cad  
67.9 72.1 53.9 57.1 60 849 29.3 33.6 26.7 28.7 30 461
90 /  1305 cad  
67.1 71.6 60.3 64.0 75 1014 28.5 33.3 29.9 32.1 40 461
100 /  1450 cad  
66.6 71.3 66.9 70.7 75 1014 27.7 32.8 33.3 35.5 40 571
110 /  1595 cad  
65.8 71.1 73.4 77.5 100 1290 - 32.5 - 39.0 40 571
120 /  1740 cad  
65.3 70.5 79.9 84.4 100 1290 - 32.2 - 42.4 50 571
 
TFS5100/ QTh1)104.1 - - - - QTh1)52.0 - - - -
10 /  145 cad  
99.9 102.0 10.6 11.7 15 313 47.8 49.9 5.1 5.8 7.5 287
20 /  290 cad  
98.8 101.2 19.3 20.9 25 355 46.8 49.1 9.5 10.5 15 287
30 /  435 cad  
97.8 100.7 28.2 30.3 40 536 45.7 48.6 13.9 15.2 20 331
40 /  580 cad  
96.7 100.1 37.0 39.6 50 582 44.6 48.1 18.2 19.8 25 368
50 /  725 cad  
95.6 99.6 45.7 48.8 60 849 43.6 47.6 22.7 24.5 30 443
60 /  870 cad  
94.6 99.1 54.6 58.2 75 1014 42.5 47.0 27.1 29.2 30 461
70 /  1015 cad  
93.8 98.5 63.4 67.5 75 1014 41.7 46.5 31.5 33.9 40 571
80 /  1160 cad  
92.7 98.0 72.1 76.8 100 1290 40.7 46.0 35.9 38.6 40 571
90 /  1305 cad  
91.9 97.5 81.0 86.1 100 1290 39.6 45.4 40.4 43.3 50 571
100 /  1450 cad  
91.1 97.2 89.8 95.3 100 1290 38.8 45.2 44.7 48.0 50 783
110 /  1595 cad  
90.4 96.7 98.6 104.7 125 1466 - 44.6 - 52.7 60 783
120 /  1740 cad  
89.3 96.4 107.4 114.0 125 1466 - 44.4 - 57.4 60 860
 
TFS5120/ QTh1)124.9 - - - - QTh1)62.5 - - - -
10 /  145 cad  
119.7 122.3 12.3 13.4 20 333 57.3 60.0 5.9 6.7 10 287
20 /  290 cad  
118.1 121.5 22.9 24.7 30 432 55.7 58.9 11.3 12.3 15 331
30 /  435 cad  
116.8 120.7 33.4 35.8 40 536 54.2 58.1 16.5 18.0 20 368
40 /  580 cad  
115.2 119.9 44.0 47.1 50 582 52.8 57.6 21.9 23.6 25 443
50 /  725 cad  
113.9 119.4 54.6 58.3 75 1014 51.5 56.8 27.1 29.2 30 461
60 /  870 cad  
112.5 118.6 65.2 69.6 75 1014 50.2 56.3 32.3 35.0 40 571
70 /  1015 cad  
111.2 118.1 75.8 80.7 100 1290 48.9 55.5 37.7 40.6 50 571
80 /  1160 cad  
110.2 117.6 86.2 92.0 100 1290 47.6 55.0 42.9 46.3 50 783
90 /  1305 cad  
108.9 117.0 96.8 103.3 125 1466 46.2 54.4 48.3 51.9 60 783
100 /  1450 cad  
107.8 116.5 107.4 114.5 125 1466 44.9 54.2 53.5 57.5 60 860
110 /  1595 cad  
106.5 116.2 118.0 125.7 150 1819 - 53.6 - 63.2 75 860
120 /  1740 cad  
105.4 115.7 128.5 136.9 150 1819 - 53.4 - 68.8 75 1092
 
TFS5130/ QTh1)135.3 - - - - QTh1)67.7 - - - -
10 /  145 cad  
129.7 132.1 13.1 15.7 20 333 62.1 64.2 6.4 7.2 10 287
20 /  290 cad  
127.9 130.8 24.7 27.2 40 536 60.2 63.1 12.1 13.1 15 331
30 /  435 cad  
126.0 129.5 36.1 38.9 50 582 58.4 61.8 17.8 19.0 20 368
40 /  580 cad  
124.4 128.4 47.6 50.4 60 849 56.8 60.8 23.6 24.9 30 461
50 /  725 cad  
122.9 127.3 59.0 62.0 75 1014 55.2 59.4 29.2 30.8 40 571
60 /  870 cad  
121.3 126.0 70.4 73.5 100 1290 53.6 58.4 35.0 36.6 40 571
70 /  1015 cad  
119.9 125.2 81.9 85.2 100 1290 52.3 57.3 40.8 42.5 50 571
80 /  1160 cad  
118.6 124.2 93.3 96.7 100 1290 51.0 56.5 46.5 48.4 50 783
90 /  1740 cad  
117.3 123.1 104.7 108.2 125 1466 49.4 55.5 52.2 54.3 60 783
100 /  1450 cad  
116.2 122.3 116.3 119.8 125 1466 48.1 54.7 57.9 60.2 75 860
110 /  1595 cad  
- 121.5 - 131.4 150 1819 - 53.9 - 66.1 75 860
120 /  1740 cad  
- 120.7 - 143.0 150 1819 - 53.1 - 72.0 75 1092
 

1) QTh: Theoretical flow rate
Viscosity > 90 SSU more power consumption.









Pumps

Quickfinder