Seite drucken

Pressure Boosting Pumps FH180

Closed impellers

Series TH and FH use closed impellers in order to minimize power consumption and to optimize hydraulic pump efficiencies.

In addition, the TH series offers high pressures at short immersion depths.

Inline pumps of the series FH can be used as boosting pumps if provided with positive inlet pressure. This inlet pressure can be provided by the central coolant supply or a feed pump. In such a setup, pumps of the series FH can raise the incoming pressure by up to 375 PSI (26 bar).

For alternating machining using internally and externally cooled tools, these models are available with Y/YY-connfigured pole-changing motor (Dahlander) for optional changeover to half speed operation.

A frequency alternator can be supplied for special applications or for matching the pump characteristic to a specific duty point.

See page "Control/Regulation" in the Technical Information section of this catalog for further information.

Applying TH/FH pumps in grinding applications

Grinding versions TH/FH pumps (-E).
TH/FH series pumps can be supplied upon request in a special grinding version for applications with heavy loads of abrasive particles (>50 HRC).
Ordering description: e.g. TH45/540-E

In this version pumps are supplied without internal diffusor gaskets in order to prevent increased wear caused by the abrasive particles in the fluid. As a result, however, the internal losses of the pump increase and the pump curves are reduced by the following percentages (valid for water based coolants).
The delivery height of the pumps will decrease as follows (valid for water based coolants):

  • TH/FH45:   18%
  • TH/FH90:   14%
  • TH/FH180:   8%
  • TH/FH360:   5% 

FH180
Please select a product.
Pumps:
  Electric specifications:
  Flow at head Height Length Weight   Power Voltage
3 Phase
Frq Rated
current
Speed
Type GPM / Feet
l/min. / m
H Inch
   mm
l Inch mm Lbs kg   HP
kW
V Hz AMPS RPM
FH180-19 40/100
140/31
25.3
643
9.33 237 84 38   2.3
1.7
220-240 50 7.1 2850
            380-420 50 4.1 2850
                  500 50 3.3 2850
                         
FH180-23 40/140
140/43
27.8
706
10.83 275 93 42   3
2.2
220-240 50 9.2 2850
            380-420 50 5.3 2850
                  500 50 4.2 2850
                         
FH180-27 40/175
140/53
29.3
744
12.32 313 99 45   3.5
2.6
220-240 50 10.9 2850
            380-420 50 6.3 2850
                  500 50 5 2850
                         
FH180-30 40/220
140/68
33.3
847
13.82 351 119 54   4.4
3.3
220-240 50 13.8 2900
            380-420 50 8 2900
                  500 50 6.4 2900
                         
FH180-38 40/275
140/87
36.3
923
16.81 427 130 59   5.4
4
220-240 50 16.5 2900
            380-420 50 9.5 2900
                  500 50 7.6 2900
                         
FH180-50 40/385
140/120
40.8
1037
21.30 541 148 67   7.4
5.5
220-240 50 22 2900
            380-420 50 12.5 2900
                  500 50 10 2900
                         
FH180-64 40/475
140/145
48.2
1225
27.28 693 179 81   10
7.5
220-240 50 29 2900
65     181 82   380-420 50 17 2900
                  500 50 13.6 2900
                         
FH180-76 40/640
140/200
54.2
1377
31.77 807 218 99   13.4
10
220-240 50 40 2900
            380-420 50 23 2900
                  500 50 18 2900

For position of terminal box, see mechanical features within the technical information section.

Motors of 10 HP and more are supplied in Δ connection.
e.g. Δ3 x 380 - 420 V, 50 Hz.
See electrical features within the technical information section.

Viton ® is a registered trademark