Immersion Pumps TB16...100
Semi-open impellers
|
Immersion Pumps are centrifugal pumps with the impeller fitted on the driving shaft extension. They are mounted on top of the container, the pump extension being immersed in the coolant.
The maximum coolant level must stay a few inches below the mounting flange.
The delivery capacities shown in the tables apply to water at 4.6 SSU (1 mm2/s) and 68°F (20°C).
For the delivery of oils, the values will decrease due to higher viscosities which result in an increased pipe resistance.
|
|
 |
 |
Please select a product.
Pumps: |
|
Electric specifications: |
| |
Flow at head |
Thread |
Depth of immersion |
Weight |
|
Power |
Voltage 3 Phase |
Frq |
Rated current |
Speed |
| Type |
GPM / Feet l/min. / m |
G |
h Inch |
mm |
Lbs |
kg |
|
HP kW |
V |
Hz |
AMPS |
RPM |
| TB16/90 |
6/6 16/2 |
G½ |
3.54 |
90 |
9.0 |
4.1 |
|
0.1 0.07 |
220-240 |
50 |
0.35 |
2800 |
| 120 |
|
4.53 |
115 |
9.5 |
4.3 |
|
380-420 |
50 |
0.2 |
2800 |
| 170 |
|
|
6.50 |
165 |
10.1 |
4.6 |
|
|
500 |
50 |
0.15 |
2800 |
| 220 |
|
|
8.46 |
215 |
10.8 |
4.9 |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
| TB25/90 |
10/6 30/2 |
G½ |
3.54 |
90 |
9.3 |
4.2 |
|
0.14 0.1 |
220-240 |
50 |
0.38 |
2700 |
| 120 |
|
4.53 |
115 |
9.7 |
4.4 |
|
380-420 |
50 |
0.22 |
2700 |
| 170 |
|
|
6.50 |
165 |
10.1 |
4.6 |
|
|
500 |
50 |
0.18 |
2700 |
| 220 |
|
|
8.46 |
215 |
11.0 |
5 |
|
|
|
|
|
|
| 270 |
|
G¾ |
10.43 |
265 |
12.1 |
5.5 |
|
|
|
|
|
|
| 350 |
|
|
13.58 |
345 |
13.4 |
6.1 |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
| TB40/90 |
13.5/6 50/2 |
G¾ |
3.74 |
95 |
9.5 |
4.3 |
|
0.16 0.12 |
220-240 |
50 |
0.44 |
2700 |
| 120 |
|
4.72 |
120 |
9.9 |
4.5 |
|
380-420 |
50 |
0.25 |
2700 |
| 170 |
|
|
6.69 |
170 |
10.4 |
4.7 |
|
|
500 |
50 |
0.2 |
2700 |
| 220 |
|
|
8.66 |
220 |
11.2 |
5.1 |
|
|
|
|
|
|
| 270 |
|
|
10.63 |
270 |
12.3 |
5.6 |
|
|
|
|
|
|
| 350 |
|
|
13.78 |
350 |
13.7 |
6.2 |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
| TB63/90 |
20/6 75/2 |
G¾ |
4.13 |
105 |
10.6 |
4.8 |
|
0.3 0.21 |
220-240 |
50 |
0.71 |
2800 |
| 120 |
|
5.12 |
130 |
11.2 |
5.1 |
|
380-420 |
50 |
0.41 |
2800 |
| 170 |
|
|
7.09 |
180 |
12.1 |
5.5 |
|
|
500 |
50 |
0.31 |
2800 |
| 220 |
|
|
9.06 |
230 |
12.8 |
5.8 |
|
|
|
|
|
|
| 270 |
|
|
11.02 |
280 |
13.4 |
6.1 |
|
|
|
|
|
|
| 350 |
|
|
14.17 |
360 |
15.2 |
6.9 |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
| TB100/120 |
24/6 100/2 |
G¾ |
5.12 |
130 |
11.5 |
5.2 |
|
0.32 0.24 |
220-240 |
50 |
0.76 |
2750 |
| 170 |
|
7.09 |
180 |
12.3 |
5.6 |
|
380-420 |
50 |
0.44 |
2750 |
| 220 |
|
|
9.06 |
230 |
13.0 |
5.9 |
|
|
500 |
50 |
0.33 |
2750 |
| 270 |
|
|
11.02 |
280 |
13.7 |
6.2 |
|
|
|
|
|
|
| 350 |
|
|
14.17 |
360 |
15.4 |
7 |
|
|
|
|
|
|
 |
 |
 |
For position of terminal box, see mechanical features within the technical information section. Standard for immersion pumps: terminal box opposite to pump discharge = position 1. Terminal box can be rotated in 90° increments.
On request G ¾ can be supplied for TB25/90 to 220 mm depth of immersion
|
|